> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/pe-add-on-opal-rt/model-in-schematic-editor/library-blocks-reference/line-blocks/cp-line-1-3-phases.md).

# CP Line (1-3) Phases

## Description

<figure><img src="https://1300141755-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FCyfrFRdgX5VC5iwM13Zm%2Fuploads%2F6Ve44OWIlZqXel2kQOpf%2Fimage.png?alt=media&amp;token=7b474895-a74d-4a7f-b6db-9f79813145c8" alt=""><figcaption></figcaption></figure>

The **Constant Parameter Line (1-3) Phases** blocks represent a transmission line, also known as distributed parameter line with lumped losses based on Bergeron's model used by the Electromagnetic Transient Program (EMTP)<sup>**\[1]**</sup>. The constant parameter (CP) line, also known as distributed parameter line, model assumes that the line parameters R, L, and C are independent of the frequency effects caused by the skin effect on phase conductors and on the ground.

{% hint style="info" %}
This block is only available in the eHS library.
{% endhint %}

## Parameters

<figure><img src="https://1300141755-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FCyfrFRdgX5VC5iwM13Zm%2Fuploads%2FNnBmis6hjIwTroOp7Qla%2Fimage.png?alt=media&amp;token=6f8ced89-3962-4800-9525-97364e0775ad" alt=""><figcaption></figcaption></figure>

| Parameter                       | Description                                                                                                                                                                                                                                                                                                                                                                                                                                  | Sets feature | I/O & monitoring |
| ------------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------ | ---------------- |
| **Line length Len (km)**        | The length of the line                                                                                                                                                                                                                                                                                                                                                                                                                       | No           | N/A              |
| **Frequency F (Hz)**            | Specifies the frequency used to compute the resistance R, inductance L, and capacitance C matrices of the line model.                                                                                                                                                                                                                                                                                                                        | No           | N/A              |
| **Parameter Entry ParamEntry**  | **Only for 2-phase and 3-phase CP lines.** Specify if RLC parameters are provided as N-by-N matrix or sequence.                                                                                                                                                                                                                                                                                                                              | No           | N/A              |
| **Resistance per km R (Ω/km)**  | <p>The resistance of the transmission line per unit length. This parameter can be set as an N-by-N matrix or sequence (2-phase and 3-phase lines only) depending on selected Parameter Entry.<br>Symmetrical lines can be specified with positive and zero-sequence resistances or N-by-N matrix.<br>Asymmetrical lines must be specified as N-by-N matrix. RLC parameters must be set using the same format(N-by-n matrix or sequence).</p> | No           | N/A              |
| **Inductance per km L(H/km)**   | The inductance of the transmission line per unit length. RLC parameters must be set using the same format(N-by-n matrix or sequence).                                                                                                                                                                                                                                                                                                        | No           | N/A              |
| **Capacitance per km C (F/km)** | The capacitance of the transmission line per unit length. RLC parameters must be set using the same format(N-by-n matrix or sequence).                                                                                                                                                                                                                                                                                                       | No           | N/A              |

## Conserving ports

| Port            | Description                                            |
| --------------- | ------------------------------------------------------ |
| **p1 to pN**    | Phase terminals on side 1 of the CP line               |
| **pN+1 to p2N** | Corresponding phase terminals on side 2 of the CP line |

***N** is the number of phases of the FD Line block.*

**For example, for the CP Line 2 Phases block:**

| Port   | Description              |
| ------ | ------------------------ |
| **p1** | Phase 1 terminal, side 1 |
| **p2** | Phase 2 terminal, side 1 |
| **p3** | Phase 1 terminal, side 2 |
| **p4** | Phase 2 terminal, side 2 |

## References <a href="#references" id="references"></a>

\[1] Dommel, H., “Digital Computer Solution of Electromagnetic Transients in Single and Multiple Networks”. IEEE Transactions on Power Apparatus and Systems, Vol. PAS-88, No. 4, April 1969.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/pe-add-on-opal-rt/model-in-schematic-editor/library-blocks-reference/line-blocks/cp-line-1-3-phases.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.