> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/rt-lab/example-models/ehs-example-models/power-electronics-example-models/boost-and-two-level-inverter.md).

# Boost and Two Level Inverter

## Description

The **Boost and Two-Level Inverter** model example demonstrates the use of the **eHSx128 solver** to compute, in real time, the outputs of an FPGA-based circuit. The FPGA-based circuit consists of a boost converter followed by a two-level DC/AC inverter, with fault insertion on the third phase.

From the menu bar, select **File > New > RT‑LAB Project**. Enter a name and location for your project, then click **Next**. From the available templates list, navigate to **eFPGASim>>Schematic\_Editor\_Workflow>>Power Electronics** and select **Boost and Two Level Inverter**, then click **Finish**.

The circuit is created using the **OPAL-RT Schematic Editor**. In this example project, users can control simulation parameters—such as input signals and gate values—in real time via the **RT-LAB console**.

## Detailed explanation

The model is composed of two main subsystems: the **Console (SC)** and the **Master (SM)**.

The **Console subsystem**, which runs on the host computer, manages communication between the host and the target simulator. It serves as the user interface during real-time simulation, allowing users to control the model and visualize the outputs of the eHS solver.

The **Master subsystem**, which runs in real time on the target simulator, manages communication between the CPU model and the eHS solver running on the FPGA. For example, parameters such as carrier frequency, output frequency, and modulation index sent from the Console are processed by the *Circuit\_Control* subsystem into frequency and duty-cycle control values. These values are then used to generate PWM signals that are sent to the Digital Output.

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-f3c9bf496734479c7aeb47bda7193b0357b7c782%2Fboost-2levelinverter-exmodel-sm.png?alt=media" alt=""><figcaption></figcaption></figure>

## Requirements

RT-LAB, Schematic Editor and the eHS Power Electronics Toolbox must be installed in order to successfully run this example project.

This project uses an external Digital Out to Digital In loopback connection to control the gates.

<details>

<summary><strong>OP5607 and OP5707 simulators</strong></summary>

In this configuration, an external Digital Output–to–Digital Input **loopback connection** must be used to control the gate signals. Connect a loopback cable from a digital output to the corresponding digital input on the simulator. This connection is required for the simulation to run successfully.

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-c295d6b5e4702def97289d92b5756a5ab5359746%2FOP5607-OP5707-loopback.png?alt=media" alt=""><figcaption></figcaption></figure>

</details>

<details>

<summary><strong>OP4512 and OP4610 simulators</strong></summary>

When configured in **bi-directional mode**, the OP5369 card supports an internal Digital Output–to–Digital Input loopback. This allows a Digital Input assigned to a channel to directly read the signal generated by the Digital Output on the same channel.

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-afa99eb09df0333f7f74ff01b5731e22fcf30a6d%2FOP4512-OP4610-loopback-interne.png?alt=media" alt=""><figcaption></figcaption></figure>

</details>

{% hint style="info" %}
If your IO Configuration contains bi-directional OP5369 card, you can always use its internal loopback capability.
{% endhint %}

## Simulation and results

<details>

<summary><strong>S-function Workflow</strong></summary>

The **Mezzanine Option block** is an RT-LAB block used in the **S-Function workflow** to configure the settings of the I/O cards for each mezzanine. The available settings depend on the specific type of I/O card.

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-f1b6053e49e0affae24fc2d39f5f8bcc8688cd6f%2Fboost-2levelinverter-exmodel-sfunction.png?alt=media" alt=""><figcaption></figcaption></figure>

</details>

<details>

<summary><strong>OpalBoard workflow</strong></summary>

[OPAL-RT Board](https://www.opal-rt.com/docs/rt-lab/configure-ios/analog-digital-and-sfp-ios/opal-rt-board-workflow.md) allow the configuration of I/O card settings for each mezzanine.

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-2f4eed5a89d21acaca1e8426fce5331e36396a68%2Fboost-2levelinverter-exmodel-opalboard.png?alt=media" alt=""><figcaption></figcaption></figure>

If, for a given I/O mezzanine, this block is not used, then the corresponding settings will be kept at their default values. These default values are dependent on particularities of the bitstream, and they are not guaranteed to be exposed to the user loading their model. Further, the default values populating the Mezzanine Option block do not necessarily correspond to the default settings that will be seen if the Mezzanine Option block is not used.

Note that if a Mezzanine Option block is used, and the choice of mezzanine type is incorrect for the given slot, the model will still load and run. However, there will be errors in the load log in RT-LAB. For example, the following error is observed in the case that slot 1A on the simulator holds an OP5330-3, when we place a Mezzanine Option block that attempts to configure an OP5369 on slot 1A:

{% code overflow="wrap" lineNumbers="true" %}

```
Mezzanine configurator: OP5369 Threshold configuration.
ERROR: OPAL-RT Board: The threshold control register for slot 1A is in an unexpected state. Please reprogram the bitstream.
ERROR: Mezzanine configurator: Threshold configuration failed...
```

{% endcode %}

Further, as documented in the aforementioned RT-LAB page, the block outputs its status: a 0 in the case when the block’s settings have been correctly applied, and a -1 otherwise. For example, in the below model I incorrectly configured one block by giving it the wrong I/O card, and set the other correctly. The result when we load the model reflects this:

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-a4fe002fb70685f86d0a022ad92068069ae7264d%2Fehs-opalboard-block-workflow.png?alt=media" alt="" width="188"><figcaption></figcaption></figure>

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-635a0707a1e24ec9979ba91be578dae9fe0d6dac%2Fehs-opalborad-model-blocks.png?alt=media" alt=""><figcaption></figcaption></figure>

</details>

### Setup Parameters <a href="#setup-parameters" id="setup-parameters"></a>

The following parameters used for real-time simulation are editable by the user inside the **initBoost2LevelInverter.m** file found in the model directory.

* **Ts:** CPU Simulation time step - the default is 20µs.
* **Boost\_Vin:** Voltage input of the boost converter
* **Boost\_PWM\_Freq:** Carrier frequency of the boost PWM generator
* **Boost\_PWM\_Duty:** Duty Cycle of the boost PWM generator
* **Inv\_PWM\_CarrierFreq:** Carrier frequency of the two-level PWM generator
* **Inv\_PWM\_ModulationIndex:** Modulation index of the two-level PWM generator
* **Inv\_PWM\_ShiftAngle:** Shift angle between the BEMF generator and the PWM/Vabc setpoints generator
* **Inv\_PWM\_Out:** AC base frequency of the two-level inverter
* **Inv\_BEMF\_Ampl:** Amplitude of the BEMF

### Run the model

Once the model has been successfully built, load and execute it in RT-LAB, you can observe the results of the eHS simulation by opening the Scope blocks in the Simulink Console.

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-bbd737ee717201cea4d73183642c70bd211a5657%2Fboost-2levelinverter-exmodel-simulation-results.png?alt=media" alt=""><figcaption></figcaption></figure>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/rt-lab/example-models/ehs-example-models/power-electronics-example-models/boost-and-two-level-inverter.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.