> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/rt-lab/model-and-simulation/phasor-domain-with-ephasorsim/integrate-a-power-system-model-to-ephasorsim/use-a-cyme-model/configuring-i-o-pins.md).

# Identify Imported Components

When a **CYME** model is imported, component names are converted to ePHASORSIM naming conventions. The resulting names, referred to as **component identifiers**, are used to identify imported components when defining **I/O pins**.

I/O pins are ports defined in an Excel configuration file that enable signal exchange between the **ePHASORSIM** power system model and the surrounding Simulink model.

Component identifiers generated during import are derived from the **Name**, **Number**, or **Section ID** fields defined in the CYME model. The table below summarizes the naming conventions used to generate component identifiers for imported CYME components. **Use these component identifiers when defining I/O pins in the Excel configuration file.**

| CYME Component                                                                                            | Converted ePHASORSIM Component Identifier                                                                                                                                                                                                                                              |
| --------------------------------------------------------------------------------------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| <p><strong>Bus / Node</strong><br>e.g., Bus with <code>Name</code> = 15</p>                               | <p><strong>bus\_\[Name]</strong><br>e.g., bus\_15<br><br>For phase-specific representations:<br><strong>bus\_\[Name]</strong><em><strong>a</strong>, <strong>bus</strong></em><strong>\[Name]</strong><em><strong>b</strong>, <strong>bus</strong></em><strong>\[Name]\_c</strong></p> |
| <p><strong>Spot Load</strong><br>e.g., Load with <code>Number</code> = 808</p>                            | <p><strong>load\_\[Number]</strong><br>e.g., load\_808</p>                                                                                                                                                                                                                             |
| <p><strong>Distributed Load</strong><br>e.g., Load with <code>Number</code> = 808\_810</p>                | <p><strong>dload\_\[Number]</strong><em><strong>from</strong></em><br><em><strong>dload</strong></em><strong>\[Number]\_to</strong><br>e.g., dload\_808\_810\_from, dload\_808\_810\_to</p>                                                                                            |
| <p><strong>Overhead Line</strong><br>e.g., Line with <code>Number</code> = 802\_to\_806</p>               | <p><strong>line\_\[Number]</strong><br>e.g., line\_802\_to\_806</p>                                                                                                                                                                                                                    |
| <p><strong>Cable</strong><br>e.g., Cable with <code>Number</code> = 5</p>                                 | <p><strong>cbl\_\[Number]</strong><br>e.g., cbl\_5</p>                                                                                                                                                                                                                                 |
| <p><strong>Busway</strong><br>e.g., Busway with <code>Number</code> = 10</p>                              | <p><strong>bw\_\[Number]</strong><br>e.g., bw\_10</p>                                                                                                                                                                                                                                  |
| <p><strong>Shunt Capacitor / Reactor</strong><br>e.g., Shunt with <code>Number</code> = 20</p>            | <p><strong>sh\_\[Number]</strong><br>e.g., sh\_20</p>                                                                                                                                                                                                                                  |
| <p><strong>Switch, breaker, fuse</strong><br>e.g., Switch with <code>Number</code> = 100</p>              | <p><strong>sw\_\[Number]</strong><br>e.g., sw\_100<br><br>Phase-specific representations:<br><strong>sw\_\[Number]</strong><em><strong>a, sw</strong></em><strong>\[Number]</strong><em><strong>b, sw</strong></em><strong>\[Number]\_c</strong></p>                                   |
| <p><strong>Recloser</strong><br>e.g., Recloser with <code>Number</code> = 15</p>                          | <p><strong>rc\_\[Number]</strong><br>e.g., rc\_15<br><br>Phase-specific representations:<br><strong>rc\_\[Number]</strong><em><strong>a, rc</strong></em><strong>\[Number]</strong><em><strong>b, rc</strong></em><strong>\[Number]\_c</strong></p>                                    |
| <p><strong>Transformer</strong><br>e.g., Transformer with <code>Number</code> = 814\_850</p>              | <p><strong>xf2w\_\[Number]</strong><br>e.g., xf2w\_814\_850</p>                                                                                                                                                                                                                        |
| <p><strong>Voltage Source</strong><br>e.g., Source with <code>Name</code> = 100</p>                       | <p><strong>vs\_\[Name]</strong><br>e.g., vs\_100</p>                                                                                                                                                                                                                                   |
| <p><strong>Voltage Regulator</strong><br>e.g., Regulator with <code>Number</code> = 66</p>                | <p><strong>vr\_\[Number]</strong><br>e.g., vr\_66</p>                                                                                                                                                                                                                                  |
| <p><strong>Electronically Coupled Generator (ECG)</strong><br>e.g., ECG with <code>Number</code> = 22</p> | <p><strong>ecg\_\[Number]</strong><br>e.g., ecg\_22</p>                                                                                                                                                                                                                                |
| <p><strong>Synchronous Generator</strong><br>e.g., Generator with <code>Number</code> = 9</p>             | <p><strong>sm\_\[Number]</strong><br>e.g., sm\_9</p>                                                                                                                                                                                                                                   |
| <p><strong>Exciter</strong><br>Associated with generator <code>Number</code> = 9</p>                      | <p><strong>exc\_\[Number]</strong><br>e.g., exc\_9</p>                                                                                                                                                                                                                                 |
| <p><strong>Governor</strong><br>Associated with generator <code>Number</code> = 9</p>                     | <p><strong>gov\_\[Number]</strong><br>e.g., gov\_9</p>                                                                                                                                                                                                                                 |
| <p><strong>Power System Stabilizer</strong><br>Associated with generator <code>Number</code> = 9</p>      | <p><strong>pss\_\[Number]</strong><br>e.g., pss\_9</p>                                                                                                                                                                                                                                 |

Note that running the simulation in Simulink, with or without configured pins, generates a `*_solver.opal` file containing the imported component identifiers.

These identifiers correspond exactly to those recognized by the solver and can be used in the **Pins** worksheet to reference components.

{% hint style="info" %}
ePHASORSIM automatically converts three-phase buses, switches, breakers, fuses, and reclosers into equivalent phase-specific representations. As a result, identifiers such as `*_a`, `*_b`, and `*_c` may be available for use in the **Pins** worksheet.
{% endhint %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/rt-lab/model-and-simulation/phasor-domain-with-ephasorsim/integrate-a-power-system-model-to-ephasorsim/use-a-cyme-model/configuring-i-o-pins.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.