> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/mmc-library/vsc_param.md).

# VSC\_Param

## Description

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-e0738ead26b2e03b5a66d2863a02e5b3d2bf2a95%2FMMC_VSC_param_block.png?alt=media" alt=""><figcaption></figcaption></figure>

The **VSC\_Param** block, located in the **MMC/VSC blocks/Conf** library, configures runtime parameters of a voltage source converter (VSC). It is typically placed in the console subsystem, and its output connects to the input of the VSC Configuration Block. The VSC model can simulate a multi-stage, multi-phase converter containing multiple two-level half-bridge (HF), full-bridge (FB) converters, three-level clamp double (CD), T-type (T-) and neutral point clamped (NPC) converters, and/or dual active bridges (DABs).

{% hint style="info" %}
Place this block in the console subsystem and connect its output to the input of the [**Conf\_sf**](https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/mmc-library/conf_sf.md) block.
{% endhint %}

## Mask parameters

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-753edca2488182a2c7df900ef75d82a87385b6cd%2FMMC_VSC_param_mask.png?alt=media" alt=""><figcaption></figcaption></figure>

{% tabs %}
{% tab title="Bridge" %}

<table><thead><tr><th width="184">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Bridge type of group 1</strong></td><td>Sets the converter type for group 1. Each group contains converter units of a single type. Supported types are Half-bridge, Full-bridge, Clamp double, T-type, and neutral point clamped.</td></tr><tr><td><strong>number of Bridges in group 1</strong></td><td>Number of converter units in group 1.</td></tr><tr><td><strong>Bridge type of group 2</strong></td><td>Sets the converter type for group 2. Each group contains converter units of a single type. Supported types are Half-bridge, Full-bridge, Clamp double, T-type, and neutral point clamped.</td></tr><tr><td><strong>number of Bridges in group 2</strong></td><td>Number of converter units in group 2.</td></tr><tr><td><strong>Bridge type of group 3</strong></td><td>Sets the converter type for group 3. Each group contains converter units of a single type. Supported types are Half-bridge, Full-bridge, Clamp double, T-type, and neutral point clamped.</td></tr><tr><td><strong>number of Bridges in group 3</strong></td><td>Number of converter units in group 3.</td></tr><tr><td><strong>IGBT/diode forward voltage</strong></td><td>Forward voltage (V).</td></tr><tr><td><strong>permanent Cap SC fault</strong></td><td><strong>Checked:</strong> Capacitor is considered damaged by a short-circuit fault and its voltage remains 0.<br><strong>Unchecked:</strong> Capacitor is not forced to 0 during a short‑circuit fault; its voltage follows the normal model dynamics.</td></tr></tbody></table>
{% endtab %}

{% tab title="Cap" %}

<table><thead><tr><th width="167">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>shunt resistance factor</strong></td><td>Multiplier applied to the capacitor discharge resistor value defined in the <a href="https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/mmc-library/conf_sf.md"><strong>Conf_sf</strong></a> block. Adjusts the effective resistance during real-time simulation.</td></tr><tr><td><strong>capacitance factor</strong></td><td>Multiplier applied to the capacitor value defined in the <a href="https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/mmc-library/conf_sf.md"><strong>Conf_sf</strong></a> block. Adjusts the effective capacitance during real-time simulation.</td></tr><tr><td><strong>Vcap mode</strong></td><td><strong>Normal operation:</strong> behaves as a capacitor<br><strong>Vcap reset to 0:</strong> resets the capacitor voltage to 0<br><strong>Vcap set to fixed value:</strong> holds the capacitor voltage at a fixed value</td></tr><tr><td><strong>Vcap fix value (SI)</strong></td><td>Fixed capacitor voltage used when <strong>Vcap mode</strong> is set to "Vcap set to fixed value".</td></tr></tbody></table>
{% endtab %}

{% tab title="DAB" %}

<table><thead><tr><th width="196">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>DAB inductor factor</strong></td><td>Multiplier applied to the DAB inductance value defined in the <a href="https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/mmc-library/conf_sf.md"><strong>Conf_sf</strong></a> block. Adjusts the effective inductance during real-time simulation.</td></tr><tr><td><strong>DAB resistor factor</strong></td><td>Multiplier applied to the DAB series resistance value defined in the <a href="https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/mmc-library/conf_sf.md"><strong>Conf_sf</strong></a> block. Adjusts the effective resistance during real-time simulation.</td></tr></tbody></table>
{% endtab %}
{% endtabs %}

## Inputs

This block has no inputs.

## Outputs

<table><thead><tr><th width="152">Output</th><th>Description</th></tr></thead><tbody><tr><td><strong>out</strong></td><td>Valve configuration signals connected to the <a href="https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/mmc-library/conf_sf.md"><strong>Conf_sf</strong></a> block in real-time subsystems.</td></tr></tbody></table>

## Characteristics and limitations

<table><thead><tr><th width="275">Characteristic</th><th>Value</th></tr></thead><tbody><tr><td>Supported converter types</td><td>Two-level half-bridge (HF), full-bridge (FB); three-level clamp double (CD), T-type (T-), neutral point clamped (NPC); dual active bridges (DABs).</td></tr><tr><td>Total SM constraint</td><td>The total number of SM across the three groups must be equal to or less than the "number of SM" set in the <a href="https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/mmc-library/conf_sf.md"><strong>Conf_sf</strong></a> block.</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/mmc-library/vsc_param.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.