> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/op8110-3-interface-group-communication.md).

# OP8110-3 Interface Group Communication

## Description

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-ba40278e1b4b5513e460bd93640eddaf34b41326%2Frtio-op8110-3interfacegrp-comm-block.png?alt=media" alt="" width="352"><figcaption></figcaption></figure>

The **OP8110-3 Interface Group Communication Block**, located in the **RT-LAB I/O/Opal-RT/OP8110** library, interfaces with **one OP8110 amplifier group**. A group consists of three amplifier outputs (for example, 1–2–3). The block configures each amplifier output’s mode within a group and applies gain and offset calibration (default gain 1, default offset 0).

This block is intended to be used in conjunction with the [OP8110-3 Interface Group GUI](https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/op8110-3-interface-group-gui.md) block and must be connected through the **GUI In** and **GUI Out** ports. When both blocks are connected, the mask of the **OP8110-3 Interface Group GUI** block automatically adapts to the **GROUP MODE** defined in the **OP8110-3 Interface Group Communication Block**—**INDEPENDENT**, **INDEPENDENT GROUPED**, or **DIFFERENTIAL**—when the model is updated or ran in Simulink (Ctrl + D).

## Mask parameters

The available parameters depend on the selected **GROUP MODE** configuration. The **Calibration** tab is common to all modes.

{% hint style="info" %}
The **Amplifier 1**, **Amplifier 2**, and **Amplifier 3** labels used in the Simulink blocks correspond to amplifier outputs **L1**, **L2**, and **L3**, respectively.
{% endhint %}

{% tabs %}
{% tab title="INDEPENDENT" %}
Parameters when **GROUP 1 MODE** is set to **INDEPENDENT** and **Grouped Operation** is **unchecked**:

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-573ebc4a58320b7364e8b3eaaf732dc2aed1b59f%2Frtio-op8110-3interfacegrp-comm-mask1.png?alt=media" alt="" width="318"><figcaption></figcaption></figure>

<table><thead><tr><th width="165.5">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>GROUP 1 MODE (AMP 1-2-3</strong>)</td><td><strong>INDEPENDENT:</strong> Each amplifier output (L1, L2, and L3) operates independently, allowing individual control of each output contactor.<br><strong>DIFFERENTIAL</strong>: Amplifier outputs L1 and L2 are operated together as a single differential amplifier. The voltage is generated between the amplifier outputs L1 and L2.</td></tr><tr><td><strong>Grouped Operation</strong></td><td><strong>Checked</strong>: Amplifier outputs L1, L2, and L3 are enabled and disabled together, and their output contactors are controlled simultaneously.<br><strong>Unchecked</strong>: Amplifier outputs L1, L2, and L3 remain independently controlled, each with its own output contactor.</td></tr><tr><td><strong>Application Mode</strong></td><td><strong>Closed Loop</strong>: Normal operating mode. This setting must always be used during standard operation.<br><strong>Open Loop</strong>: Debug and installation mode intended for OPAL‑RT engineering use only. Not intended for normal operation.</td></tr><tr><td><strong>AMPLIFIER </strong><em><strong>x</strong></em><strong> ENABLE MODE</strong></td><td><strong>GUI OUTPUT ENABLE</strong>: The L<em>x</em> output contactor is controlled from the <strong>OP8110‑3 Console GUI</strong>.<br><strong>MODEL OUTPUT ENABLE</strong>: The L<em>x</em> output contactor is controlled by the corresponding <strong>Amp X Enable</strong> input port of the <strong>OP8110-3 Interface Group Communication Block</strong>.</td></tr><tr><td><strong>Bypass output inductance Amp</strong><em><strong>x</strong></em></td><td><strong>Checked</strong>: Bypasses the <strong>75 µH output inductance</strong> from the amplifier L<em>x</em> output path.<br><strong>Unchecked</strong>: Keeps the <strong>75 µH output inductance</strong> in the circuit for amplifier L<em>x</em> output. <em>(Default setting)</em></td></tr></tbody></table>
{% endtab %}

{% tab title="INDEPENDENT GROUPED" %}
Parameters when **GROUP 1 MODE** is set to **INDEPENDENT** and **Grouped Operation** is **checked**:

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-708b01bb82bdcca50259c7343cd6a231030d3000%2Frtio-op8110-3interfacegrp-comm-mask2.png?alt=media" alt="" width="318"><figcaption></figcaption></figure>

<table><thead><tr><th width="165.5">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>GROUP 1 MODE (AMP 1-2-3</strong>)</td><td><strong>INDEPENDENT:</strong> Each amplifier output (L1, L2, and L3) operates independently, allowing individual control of each output contactor.<br><strong>DIFFERENTIAL</strong>: Amplifier outputs L1 and L2 are operated together as a single differential amplifier. The voltage is generated between the amplifier outputs L1 and L2.</td></tr><tr><td><strong>Grouped Operation</strong></td><td><strong>Checked</strong>: Amplifier outputs L1, L2, and L3 are enabled and disabled together, and their output contactors are controlled simultaneously.<br><strong>Unchecked</strong>: Amplifier outputs L1, L2, and L3 remain independently controlled, each with its own output contactor.</td></tr><tr><td><strong>Application Mode</strong></td><td><strong>Closed Loop</strong>: Normal operating mode. This setting must always be used during standard operation.<br><strong>Open Loop</strong>: Debug and installation mode intended for OPAL‑RT engineering use only. Not intended for normal operation.</td></tr><tr><td><strong>AMPLIFIER GROUP ENABLE MODE</strong></td><td><strong>GUI OUTPUT ENABLE</strong>: All amplifier outputs in the group are controlled together from the <strong>OP8110‑3 Console GUI</strong>.<br><strong>MODEL OUTPUT ENABLE</strong>: The amplifier L<em>x</em> output is controlled by the corresponding <strong>Amp </strong><em><strong>x</strong></em><strong> Enable</strong> input port of the <strong>OP8110-3 Interface Group Communication Block</strong>. All amplifier outputs operate independently in this case.</td></tr><tr><td><strong>Bypass output inductance</strong></td><td><strong>Checked</strong>: Bypasses the <strong>75 µH output inductance</strong> from the amplifier output path.<br><strong>Unchecked</strong>: Keeps the <strong>75 µH output inductance</strong> in the circuit. <em>(Default setting)</em></td></tr></tbody></table>
{% endtab %}

{% tab title="DIFFERENTIAL" %}
Parameters when **GROUP 1 MODE** is set to **DIFFERENTIAL**:

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-8bf69e46994286773e683a9a9298d4aa7ca96921%2Frtio-op8110-3interfacegrp-comm-mask3.png?alt=media" alt="" width="318"><figcaption></figcaption></figure>

<table><thead><tr><th width="165.5">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>GROUP 1 MODE (AMP 1-2-3</strong>)</td><td><strong>DIFFERENTIAL</strong>: Amplifier outputs L1 and L2 are operated together as a single differential amplifier. The voltage is generated between the amplifier outputs L1 and L2.<br><strong>INDEPENDENT:</strong> Each amplifier output (L1, L2, and L3) operates independently, allowing individual control of each output contactor.</td></tr><tr><td><strong>Application Mode</strong></td><td><strong>Closed Loop</strong>: Normal operating mode. This setting must always be used during standard operation.<br><strong>Open Loop</strong>: Debug and installation mode intended for OPAL‑RT engineering use only. Not intended for normal operation.</td></tr><tr><td><strong>Bypass output inductance Amp</strong><em><strong>X</strong></em></td><td><strong>Checked</strong>: Bypasses the <strong>75 µH output inductance</strong> from the amplifier L<em>x</em> output path.<br><strong>Unchecked</strong>: Keeps the <strong>75 µH output inductance</strong> in the circuit for amplifier L<em>x</em> output. <em>(Default setting)</em></td></tr><tr><td><strong>AMPLIFIER GROUP ENABLE MODE</strong></td><td><strong>GUI OUTPUT ENABLE</strong>: All amplifier outputs in the group are controlled together from the <strong>OP8110‑3 Console GUI</strong>.<br><strong>MODEL OUTPUT ENABLE</strong>: The amplifier L<em>x</em> output is controlled by the corresponding <strong>Amp </strong><em><strong>x</strong></em><strong> Enable</strong> input port of the <strong>OP8110-3 Interface Group Communication Block</strong>. All amplifier outputs operate independently in this case.</td></tr></tbody></table>
{% endtab %}

{% tab title="Calibration" %}
The **Calibration** tab is common to all modes.

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-34ae14450c2a67b0373eaca7335b8d8bf6e749a8%2Frtio-op8110-3interfacegrp-comm-mask4.png?alt=media" alt="" width="318"><figcaption></figcaption></figure>

<table><thead><tr><th width="261">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Amplifier </strong><em><strong>x</strong></em><strong> Gain Correction</strong></td><td>Gain correction factor multiplied with the Amp <em>x</em> Vref signal before it is sent to the amplifier output L<em>x</em>. Default: 1.</td></tr><tr><td><strong>Amplifier </strong><em><strong>x</strong></em><strong> Offset Correction</strong></td><td>Offset correction value added to the Amp <em>x</em> Vref signal before it is sent to the amplifier output L<em>x</em>. Default: 0.</td></tr></tbody></table>
{% endtab %}
{% endtabs %}

## Inputs

<table><thead><tr><th width="154">Input</th><th>Description</th></tr></thead><tbody><tr><td><strong>GUI_In</strong></td><td>Inputs control commands from the <a href="https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/op8110-3-interface-group-gui.md">OP8110‑3 Interface Group GUI</a> block.<br>This port must be connected to the output port of the OP8110‑3 Interface Group GUI block.</td></tr><tr><td><strong>Amp </strong><em><strong>x</strong></em><strong> Enable</strong></td><td>A value of <code>1</code> enables the L<em>x</em> output contactorand a value of <code>0</code> disables it.<br><em>This input is</em> i<em>nactive when <strong>AMPLIFIER GROUP X ENABLE MODE</strong> is set to <strong>GUI OUTPUT ENABLE.</strong></em></td></tr><tr><td><strong>Amp </strong><em><strong>x</strong></em><strong> Vref</strong></td><td>Inputs the voltage reference for amplifier output L<em>x</em>. The value corresponds to the amplifier L<em>x</em> output voltage (phase-to-neutral). In <strong>DIFFERENTIAL</strong> mode, it corresponds to the output voltage between amplifier phase L1 and phase L2.</td></tr><tr><td><strong>SFP to OpInput</strong></td><td>Connect an OpInput block with tag SFP00 (or SFP01 for a second unit, etc.) to establish communication with the amplifier. The mapping procedure between the amplifier bitstream I/O and model I/O tags is described in <a href="https://opal-rt.atlassian.net/wiki/spaces/PSSDD/pages/144677020/OP1400+PHIL+Test+Bench+Series+Interfacing+through+RT-LAB">Simulator SFP Communication Setup</a>.</td></tr></tbody></table>

## Outputs

<table><thead><tr><th width="198">Output</th><th>Description</th></tr></thead><tbody><tr><td><strong>GUI_out</strong></td><td>Outputs monitoring information to the <a href="https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/op8110-3-interface-group-gui.md">OP8110‑3 Interface Group GUI</a> block. This port must be connected to the input port of the OP8110‑3 Interface Group GUI block.</td></tr><tr><td><strong>Global Status</strong></td><td>Outputs the global status of the amplifier group. Intended for troubleshooting by OPAL‑RT experts only.</td></tr><tr><td><strong>Amp </strong><em><strong>x</strong></em><strong> Status</strong></td><td>Outputs the status of amplifier output L<em>x</em>. Intended for troubleshooting by OPAL‑RT experts only.</td></tr><tr><td><strong>Amp </strong><em><strong>x</strong></em><strong> Measure</strong></td><td><p>Provides measurements from amplifier output L<em>x</em>:</p><ul><li>Measured output voltage (In <strong>DIFFERENTIAL</strong> mode, this measurement corresponds to the voltage difference between L1 and L2).</li><li>Measured output current.</li><li>Measured voltage on the remote voltage connection.</li></ul></td></tr><tr><td><strong>SFP to OpOutput</strong></td><td>Connect an OpOutput block with tag SFP00 (or SFP01 for a second unit, etc.) to establish communication with the amplifier. The mapping procedure between the amplifier bitstream I/O and model I/O tags is described in <a href="https://opal-rt.atlassian.net/wiki/spaces/PSSDD/pages/144677020/OP1400+PHIL+Test+Bench+Series+Interfacing+through+RT-LAB">Simulator SFP Communication Setup</a>.</td></tr></tbody></table>

## Characteristics and limitations

<table><thead><tr><th width="245.25">Characteristic</th><th>Value</th></tr></thead><tbody><tr><td><strong>Block inputs and outputs</strong></td><td>The block input and output are static and do not change based on the configured mode or operation settings. <strong>Some ports may therefore be unused</strong> depending on the selected configuration.</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/op8110-3-interface-group-communication.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.