> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/op8110-6-interface-group-gui.md).

# OP8110-6 Interface Group GUI

## Description

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-2f1f6ab4525000411d6dfe973e8d76b8b0a33105%2Frtlio-op8110-6interfacegrp-gui-block.png?alt=media" alt=""><figcaption></figcaption></figure>

The **OP8110-6 Interface Group GUI** block, located in the **RT-LAB I/O/Opal-RT/OP8110** library, provides an interactive graphical interface for monitoring and controlling the input DC-Link and individual outputs of **two** **OP8110 amplifier groups**. The GUI displays system and amplifier fault status and allows the user to **enable or disable the DC link and individual amplifier outputs**.

This block is intended to be used in conjunction with the [OP8110- Interface Group Communication Block](https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/op8110-6-interface-group-communication.md) and must be connected through the **GUI In** and **GUI Out** ports. When both blocks are connected, the mask of the **OP8110-6 Interface Group GUI** block automatically adapts to the **GROUP MODE** defined in the **OP8110-6 Interface Group Communication Block**—**INDEPENDENT**, **INDEPENDENT GROUPED**, or **DIFFERENTIAL**—when the model is updated or ran in Simulink (Ctrl + D).

## Mask parameters

This block has no configurable parameters.

Opening the block mask provides access to graphical user interfaces used to **monitor and control OP8110 amplifiers**. The available GUI layout and controls depend on the configuration of the **OP8110‑6 Interface Group Communication** **Block**. This section describes the GUI behavior and associated controls when **both amplifier groups** are configured in **INDEPENDENT**, **INDEPENDENT GROUPED**, or **DIFFERENTIAL** modes. Note that the two groups can be configured **independently** (for example, one group in **INDEPENDENT** mode and the other in **INDEPENDENT GROUPED** mode). For such mixed configurations, refer to the **two corresponding tabs** described below.

{% hint style="info" %}
The **Amplifier 1** through **Amplifier 6** labels used in the Simulink blocks correspond to the physical amplifier outputs **L1** through **L6**, respectively.
{% endhint %}

{% tabs %}
{% tab title="INDEPENDENT" %}
**OP8110-6 Interface Group GUI** when the **OP8110-6 Interface Group Communication Block** is configured with **GROUP 1 MODE** and **GROUP 2 MODE** set to **INDEPENDENT** and **Grouped Operation** is **unchecked** for both groups:

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-9fccb9db4eb9300a0d555190232d8871b1470381%2Frtlio-op8110-6interfacegrp-gui-mask1.png?alt=media" alt="" width="563"><figcaption></figcaption></figure>

<table><thead><tr><th width="160.5">Section</th><th>Description</th></tr></thead><tbody><tr><td><strong>STATUS GLOBAL</strong></td><td>Displays the overall operating status of the OP8110 system. Shows <strong>SYSTEM IS OK</strong> when no system fault is detected and <strong>FAULT</strong> when a system‑level fault is present.<br>Also displays the current amplifier group operating mode: <strong>INDEPENDENT</strong>, <strong>GROUPED</strong>, or <strong>DIFFERENTIAL</strong>.<br>The <strong>RESET ALL</strong> button clears any amplifier faults and returns the unit to its initial state, ready for re‑initialization.</td></tr><tr><td><strong>GROUP 1: DC BUS / GROUP 2: DC BUS</strong></td><td>Displays and controls the <strong>DC link status</strong> for the amplifier group. <strong>Enable Amplifier DC Link</strong> pre‑charges and enables the DC link.<br><strong>DISABLE</strong> disconnects the DC link from the amplifier.<br>The DC bus status is shown as <strong>DC BUS ON!!</strong> when enabled/pre‑charged and <strong>OFF</strong> when disabled.</td></tr><tr><td><strong>AMPLIFIER </strong><em><strong>x</strong></em><strong>: VOLTAGE CONTROL</strong></td><td>Displays whether the amplifier L<em>x</em> output is in <strong>GUI CONTROL MODE</strong> or <strong>MODEL CONTROL MODE</strong>, as configured in the <strong>OP8110‑6 RT‑LAB Communication Block</strong>.<br><strong>ENABLE OUTPUT</strong> turns the amplifier L<em>x</em> output ON.<br><strong>DISABLE</strong> turns it off.<br>Status indicators include <strong>OFF</strong> (output disabled), <strong>FAULTY LEG!!</strong> (fault condition), and <strong>OUTPUT ON!!</strong> (output enabled and powered).</td></tr></tbody></table>
{% endtab %}

{% tab title="INDEPENDENT GROUPED" %}
**OP8110-6 Interface Group GUI** when the **OP8110-6 Interface Group Communication Block** is configured with **GROUP 1 MODE** and **GROUP 2 MODE** set to **INDEPENDENT** and **Grouped Operation** is **checked** for both groups:

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-0da3b01b197630626e1aa2121c475e32630a31ac%2Frtlio-op8110-6interfacegrp-gui-mask2.png?alt=media" alt="" width="563"><figcaption></figcaption></figure>

<table><thead><tr><th width="160.5">Section</th><th>Description</th></tr></thead><tbody><tr><td><strong>STATUS GLOBAL</strong></td><td>Displays the overall operating status of the OP8110 system. Shows <strong>SYSTEM IS OK</strong> when no system fault is detected and <strong>FAULT</strong> when a system‑level fault is present.<br>Also displays the current amplifier group operating mode: <strong>INDEPENDENT</strong>, <strong>GROUPED</strong>, or <strong>DIFFERENTIAL</strong>.<br>The <strong>RESET ALL</strong> button clears any amplifier faults and returns the unit to its initial state, ready for re‑initialization.</td></tr><tr><td><strong>GROUP 1: DC BUS / GROUP 2: DC BUS</strong></td><td>Displays and controls the <strong>DC link status</strong> for the amplifier group. <strong>Enable Amplifier DC Link</strong> pre‑charges and enables the DC link.<br><strong>DISABLE</strong> disconnects the DC link from the amplifier.<br>The DC bus status is shown as <strong>DC BUS ON!!</strong> when enabled/pre‑charged and <strong>OFF</strong> when disabled.</td></tr><tr><td><strong>AMPLIFIER 1: VOLTAGE CONTROL</strong></td><td>Displays whether the amplifier L1, L2 and L3 outputs are in <strong>GUI CONTROL MODE</strong> or <strong>MODEL CONTROL MODE</strong>, as configured in the <strong>OP8110‑6 RT‑LAB Communication Block</strong>.<br><strong>ENABLE OUTPUT</strong> turns the all amplifier outputs ON.<br><strong>DISABLE</strong> turns them off.<br>Status indicators include <strong>OFF</strong> (output disabled), <strong>FAULTY LEG!!</strong> (fault condition), and <strong>OUTPUT ON!!</strong> (output enabled and powered).</td></tr><tr><td><strong>AMPLIFIER 4: VOLTAGE CONTROL</strong></td><td>Displays whether the amplifier L4, L5 and L6 outputs are in <strong>GUI CONTROL MODE</strong> or <strong>MODEL CONTROL MODE</strong>, as configured in the <strong>OP8110‑6 RT‑LAB Communication Block</strong>.<br><strong>ENABLE OUTPUT</strong> turns the all amplifier outputs ON.<br><strong>DISABLE</strong> turns them off.<br>Status indicators include <strong>OFF</strong> (output disabled), <strong>FAULTY LEG!!</strong> (fault condition), and <strong>OUTPUT ON!!</strong> (output enabled and powered).</td></tr></tbody></table>
{% endtab %}

{% tab title="DIFFERENTIAL" %}
**OP8110-6 Interface Group GUI** when the **OP8110-6 Interface Group Communication Block** is configured with **GROUP 1 MODE** and **GROUP 2 MODE** set to **DIFFERENTIAL**:

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-fcdcb0a0ea0f575106ab61251732dcb0551b9343%2Frtlio-op8110-6interfacegrp-gui-mask3.png?alt=media" alt="" width="563"><figcaption></figcaption></figure>

<table><thead><tr><th width="160.5">Section</th><th>Description</th></tr></thead><tbody><tr><td><strong>STATUS GLOBAL</strong></td><td>Displays the overall operating status of the OP8110 system. Shows <strong>SYSTEM IS OK</strong> when no system fault is detected and <strong>FAULT</strong> when a system‑level fault is present.<br>Also displays the current amplifier group operating mode: <strong>INDEPENDENT</strong>, <strong>GROUPED</strong>, or <strong>DIFFERENTIAL</strong>.<br>The <strong>RESET ALL</strong> button clears any amplifier faults and returns the unit to its initial state, ready for re‑initialization.</td></tr><tr><td><strong>GROUP 1: DC BUS / GROUP 2: DC BUS</strong></td><td>Displays and controls the <strong>DC link status</strong> for the amplifier group. <strong>Enable Amplifier DC Link</strong> pre‑charges and enables the DC link.<br><strong>DISABLE</strong> disconnects the DC link from the amplifier.<br>The DC bus status is shown as <strong>DC BUS ON!!</strong> when enabled/pre‑charged and <strong>OFF</strong> when disabled.</td></tr><tr><td><strong>AMPLIFIER 1: VOLTAGE CONTROL</strong></td><td>Displays whether the amplifier L1 and L2 outputs are in <strong>GUI CONTROL MODE</strong> or <strong>MODEL CONTROL MODE</strong>, as configured in the <strong>OP8110‑3 RT‑LAB Communication Block</strong>.<br><strong>ENABLE OUTPUT</strong> turns the amplifier L1 and L2 outputs ON.<br><strong>DISABLE</strong> turns them off.<br>Status indicators include <strong>OFF</strong> (output disabled), <strong>FAULTY LEG!!</strong> (fault condition), and <strong>OUTPUT ON!!</strong> (output enabled and powered).</td></tr><tr><td><strong>AMPLIFIER 4: VOLTAGE CONTROL</strong></td><td>Displays whether the amplifier L4 and L5 outputs are in <strong>GUI CONTROL MODE</strong> or <strong>MODEL CONTROL MODE</strong>, as configured in the <strong>OP8110‑6 RT‑LAB Communication Block</strong>.<br><strong>ENABLE OUTPUT</strong> turns the all amplifier L4 and L5 outputs ON.<br><strong>DISABLE</strong> turns them off.<br>Status indicators include <strong>OFF</strong> (output disabled), <strong>FAULTY LEG!!</strong> (fault condition), and <strong>OUTPUT ON!!</strong> (output enabled and powered).</td></tr></tbody></table>
{% endtab %}
{% endtabs %}

## Inputs

<table><thead><tr><th width="150.25">Input</th><th>Description</th></tr></thead><tbody><tr><td><strong>Input</strong></td><td>Inputs monitoring information from the <a href="https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/op8110-6-interface-group-communication.md">OP8110-6 Interface Group Communication Block</a>. This input must be connected to the <strong>GUI Out</strong> output port of the OP8110‑6 Interface Group Communication block.</td></tr></tbody></table>

## Outputs

<table><thead><tr><th width="150.25">Output</th><th>Description</th></tr></thead><tbody><tr><td><strong>Output</strong></td><td>Outputs control commands to the <a href="https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/op8110-6-interface-group-communication.md">OP8110-6 Interface Group Communication Block</a>. This port must be connected to the <strong>GUI In</strong> input of the OP8110-6 Interface Group Communication Block.</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/op8110-6-interface-group-gui.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.