> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/pwm-in.md).

# PWM In

## Description

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-2a22ca4604463420368731c5e6ec0397847fb37f%2F0f03761b-698a-484f-b736-f75be1d872d8.png?alt=media" alt=""><figcaption></figcaption></figure>

The **PWM In** block, located in the **RT-LAB I/O/Opal-RT/Common** library, retrieves a PWM duty cycle and frequency per time step per channel from a Digital Input module installed in the simulator or expansion unit.

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-a31fdb0604010d578e893b7facc9bae650472d85%2Fpwm.png?alt=media" alt=""><figcaption></figcaption></figure>

## Mask parameters

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-cafb8a0e6054c50ba6b2187189667e4b3cca717f%2F9ad8b26b-b973-4428-a74f-ea90e5e27dce.png?alt=media" alt="" width="329"><figcaption></figcaption></figure>

<table><thead><tr><th width="195">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Controller Name</strong></td><td>Specifies the <strong>OpCtrl</strong> block this block is bound to. Enter the same <strong>Controller Name</strong> as defined in the corresponding <strong>OpCtrl</strong> block.</td></tr><tr><td><strong>DataOut port number</strong></td><td>Specifies the Digital Input module and subsection from which this block acquires signals. Subsection 1 corresponds to channels 0–7, subsection 2 corresponds to channels 8–15, and so on.<br>Configure the <strong>DataIn port number</strong> according to your <strong>System Description Document</strong> or <code>.conf</code> file.</td></tr><tr><td><strong>Slot infos</strong></td><td>Read‑only field displaying the expected physical location (Slot, Section, Subsection) of the Digital Input module derived from the selected <strong>DataIn port number</strong>. If the port number is invalid, <em>Slot 0 Module X Subsection 0</em> is displayed.</td></tr><tr><td><strong>Available channels</strong></td><td>Read‑only field displaying the maximum number of channels available in the selected subsection.</td></tr><tr><td><strong>Number of PWM lines</strong></td><td>Specifies the size of the block output vector, corresponding to the number of channels returned at each calculation step. The value must be less than or equal to the <strong>Available channels</strong>. Due to the data transfer mechanism, channels cannot be individually selected; the block returns data for the first N channels of the subsection, where <em>N</em> is this parameter.</td></tr><tr><td><strong>Sample time (s)</strong></td><td><p>Specifies the block sample time, in seconds. A value of <code>0</code> sets a continuous sample time, inherited from the parent subsystem. A value of <code>−1</code> specifies an inherited sample time from the model.</p><p>The functionality block and its associated <strong>OpCtrl</strong> block must execute at the same <strong>sample time</strong>.</p></td></tr></tbody></table>

## Inputs

This block has no inputs.

## Outputs

<table><thead><tr><th width="129.75">Output</th><th>Description</th></tr></thead><tbody><tr><td><strong>Hz</strong></td><td>Outputs the acquired PWM carrier frequencies for the selected channel subset. The output vector size is determined by the <strong>Number of PWM lines</strong> parameter. Use a <strong>Demux</strong> block to access individual channel signals.<br>Returns <code>0</code> when the line is disconnected. Minimum measurable frequency: 100 Hz.</td></tr><tr><td><strong>Duty</strong></td><td>Outputs the acquired PWM duty cycles (from <code>0</code> to <code>1</code>) for the selected channel subset. The output vector size is determined by the <strong>Number of PWM lines</strong> parameter. Use a <strong>Demux</strong> block to access individual channel signals.<br>Returns <code>0</code> when the line is disconnected. Minimum measurable frequency: 100 Hz.</td></tr><tr><td><strong>Status</strong></td><td><p>Outputs the block status:</p><ul><li><code>0</code>: No error.</li><li><code>-1</code>: Block not associated with an <strong>OpCtrl</strong> block (check the <strong>Controller Name</strong> parameter), or FPGA initialization failure.</li><li><code>-2</code>: Data reception timeout, typically caused by model synchronization issues.</li><li><code>-3</code>: Data reception error: fewer data received than expected. Missing values are replaced with <code>0</code>.</li><li><code>-4</code>: Data reception error: more data received than expected. Extra values are discarded.</li></ul></td></tr></tbody></table>

## Characteristics and limitations

<table><thead><tr><th width="241">Characteristic</th><th>Value</th></tr></thead><tbody><tr><td><strong>Connector pin assignments</strong></td><td>Refer to the <strong>System Description Document</strong> provided with your order, or refer to the pin assignment of the <a href="https://opal-rt-technologies.gitbook.io/opal-rt-technologies-docs/op53xx/"><strong>OP53xx series I/O module</strong></a> associated with each subsection.</td></tr><tr><td><strong>Unexpected behavior</strong></td><td>If the duty cycle value from the bitstream is non-zero and the period is zero, negative values may be output. This may indicate a wrong bitstream file.</td></tr><tr><td><strong>Frequency range (Hz)</strong></td><td>100 to 190 kHz (to ensure correct functionality)</td></tr><tr><td><strong>Max channels per sub-section</strong></td><td>8</td></tr><tr><td><strong>Direct feedthrough</strong></td><td>No</td></tr><tr><td><strong>Discrete sample time</strong></td><td>Yes</td></tr><tr><td><strong>XHP support</strong></td><td>Yes</td></tr><tr><td><strong>Work offline</strong></td><td>No</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/rt-lab-i-o-library/pwm-in.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.