> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/smart-inverter-library/gfm-signal-conditioning-three-phase.md).

# GFM Signal Conditioning Three Phase

## Description

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-0bc0a409c2528f07ed88ae86a2dfdbaaa0e5ee3f%2FCSI_RT_GFM_signal_condition_3P_block.png?alt=media" alt="" width="137"><figcaption></figcaption></figure>

The \*\*Signal Conditioning\*\* block, located in the \*\*Smart Inverter Library\*\*, converts measured voltage and current signals at various locations to per-unit values and transforms them into d–q coordinates using a cosine‑based Park transformation. At t = 0, the d‑axis of the rotating frame is aligned with phase A. The block also filters the measured DC-link voltage and converts it to per-unit.

{% hint style="danger" %}
This block requires a valid license on both the simulator and the workstation with the feature SMART INVERTER enabled.
{% endhint %}

## Mask parameters

<figure><img src="https://96827845-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FNRdpSk8kjn20gXAexnt6%2Fuploads%2Fgit-blob-3bac08cc7e035d79646c93e6ea2df3a932a35986%2FCSI_RT_GFM_signal_condition_3P_mask.png?alt=media" alt=""><figcaption></figcaption></figure>

<table><thead><tr><th width="190">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Nominal Operating Voltage</strong></td><td>Nominal line-to-line RMS voltage of the grid-forming converter (V)</td></tr><tr><td><strong>Nominal Power</strong></td><td>Nominal apparent power rating of the grid-forming converter (VA)</td></tr><tr><td><strong>Nominal Frequency</strong></td><td>Nominal operating frequency of the grid-forming converter (Hz)</td></tr><tr><td><strong>Nominal DC voltage</strong></td><td>Nominal DC-link input voltage of the inverter (V)</td></tr><tr><td><strong>DC Link Voltage Measurement Filter Cut-off Frequency</strong></td><td>Cut-off frequency of the DC-link voltage measurement low-pass filter (rad/s)</td></tr><tr><td><strong>Sample Time</strong></td><td>Input sampling period (s)</td></tr></tbody></table>

## Inputs

| Input    | Description                                                                                           |
| -------- | ----------------------------------------------------------------------------------------------------- |
| **Iinv** | Current at the inverter-side filter inductor (A)                                                      |
| **Io**   | Output current measured at the filter output (A)                                                      |
| **Vo**   | Per-phase output voltage measured across the filter capacitor (V)                                     |
| **Vdc**  | Measured DC-link voltage (V)                                                                          |
| **wt**   | Electrical angle synchronized to zero crossings of the fundamental positive-sequence of phase A (rad) |

## Outputs

| Output            | Description                                                                          |
| ----------------- | ------------------------------------------------------------------------------------ |
| **Frequency\_pu** | Per-unit frequency of the inverter output voltage (pu)                               |
| **Vo\_RMS**       | RMS value of the output voltage (V)                                                  |
| **Vo\_dq\_pu**    | Per-unit direct and quadrature components of the output voltage (pu)                 |
| **Io\_pu**        | Per-unit output current measured at the filter output (pu)                           |
| **Io\_dq\_pu**    | Per-unit direct and quadrature components of the output current (pu)                 |
| **Iinv\_pu**      | Per-unit current measured at the inverter-side filter inductor (pu)                  |
| **Iinv\_dq\_pu**  | Per-unit direct and quadrature components of the inverter-side inductor current (pu) |
| **Vdc\_pu**       | Per-unit measured DC-link voltage (pu)                                               |

## Signals available for monitoring and external I/O connections (via sensors form)

All block inputs and outputs are available as signals for monitoring and for external I/O connections.

{% hint style="danger" %}

## **Intellectual Property Disclaimer**

Natural Resources Canada owns all intellectual property rights in the Smart Inverter Modelling Toolbox software and related products.
{% endhint %}

{% hint style="info" %}

## Acknowledgements <a href="#acknowledgements" id="acknowledgements"></a>

The development of the <code class="expression">page.vars.block\_name</code> block in the Smart Inverter Control Library is a contribution of CanmetENERGY at Natural Resource Canada.
{% endhint %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/rt-lab/simulink-blocks-reference/smart-inverter-library/gfm-signal-conditioning-three-phase.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
