> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/smart-power-simulation-software-sps/blocks-functions-tools/basics/passives/parallel-rlc-load.md).

# Parallel RLC Load

## Description

<figure><img src="https://799605156-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FdlNg8IbOdahCpFCyzxSN%2Fuploads%2Fgit-blob-03615085ad2717e28475746ddc4ba4865ecf005b%2Fparallel_RLC_load-block.png?alt=media" alt=""><figcaption></figcaption></figure>

The **Parallel RLC Load** block, located in the **OPAL-RT SPS Software/Passives** library, implements a linear load as a parallel combination of RLC elements. At the specified frequency, the load exhibits a constant impedance. The active and reactive powers absorbed by the load are proportional to the square of the applied voltage.

Only elements associated with nonzero powers are displayed in the block icon.

## Parameters

<table><thead><tr><th width="145.99993896484375">Parameter</th><th>Description</th></tr></thead><tbody><tr><td>Nominal voltage Vn</td><td>The nominal voltage of the load, in volts RMS (Vrms). Default is <code>1000</code>.</td></tr><tr><td>Nominal frequency fn</td><td>The nominal frequency, in hertz (Hz). Default is <code>60</code>.</td></tr><tr><td>Active power P</td><td>The active power of the load, in watts. Default is <code>10e3</code>.</td></tr><tr><td>Inductive reactive power QL</td><td>The inductive reactive power QL, in vars. Specify a positive value, or 0. Default is <code>100</code>.</td></tr><tr><td>Capacitive reactive power QC</td><td>The capacitive reactive power QC, in vars. Specify a positive value, or 0. Default is <code>100</code>.</td></tr><tr><td>Set the initial capacitor voltage</td><td>If selected, the initial capacitor voltage is defined by the <strong>Capacitor initial voltage</strong> parameter. If cleared, the software calculates the initial capacitor voltage to start the simulation in steady-state. Default is cleared. This parameter has no effect if the capacitive reactive power is equal to zero.</td></tr><tr><td>Capacitor initial voltage (V)</td><td>The initial capacitor voltage used at the start of the simulation. This parameter has no effect if the capacitive reactive power is equal to zero and if <strong>Set the initial capacitor voltage</strong> is cleared. Default is <code>0</code>.</td></tr><tr><td>Set the initial inductor current</td><td>If selected, the initial inductor current is defined by the <strong>Inductor initial current</strong> parameter. If cleared, the software calculates the initial inductor current to start the simulation steady-state. Default is cleared. This parameter has no effect if the inductive reactive power is equal to zero.</td></tr><tr><td>Inductor initial current (A)</td><td>The initial inductor current used at the start of the simulation. This parameter has no effect if the inductive reactive power is equal to zero and if <strong>Set the initial inductor current</strong> is cleared. Default is <code>0</code>.</td></tr><tr><td>Measurements</td><td>Select <code>Branch voltage</code> to measure the voltage across the Parallel RLC Load block terminals. Select <code>Branch current</code> to measure the current flowing through the Parallel RLC Load block. Select <code>Branch voltage and current</code> to measure both. Default is <code>None</code>. Place a Multimeter block in your model to display the selected measurements during the simulation. In the <strong>Available Measurements</strong> list box of the Multimeter block, the measurement is identified by a label followed by the block name<br>Labels for Measurements:<br>Branch voltage- Ub:<br>Branch current - Ib:</td></tr></tbody></table>

### Load Flow

The Load Flow tool of the powergui block uses the parameters on this tab. These load flow parameters affect only model initialization. They do not affect simulation.

* Load type — Specify the load type. The default value is `constant Z`.
  * If `constant Z` is selected, the load impedance is determined from the nominal phase-to-phase voltage Vn, active power P, and reactive power (QL - QC) specified on the **Parameters** tab. During the load flow solution, the impedance is kept constant. The effective P and Q therefore vary proportionally to the square of the bus voltage computed by the Load Flow tool.
  * If `constant PQ` is selected, the active power P and reactive power Q are kept constant and equal to the values specified on the **Parameters** tab. When you apply the load flow solution to the model (by clicking **Apply** in the Load Flow tool), the **Nominal phase-to-phase voltage Vn** parameter on the **Parameters** tab is automatically adjusted to the phase-to-phase bus voltage computed by the Load Flow tool.
  * If `constant I` is selected, the load current is kept constant at its nominal value determined from the base voltage specified in the dialog box of the associated Load Flow Bus block and from active power P and reactive power QL and QC specified on the **Parameters** tab. The effective P and Q therefore vary proportionally to the bus voltage computed by the Load Flow tool. When you apply the load flow solution to the model (by clicking **Apply** in the Load Flow tool), the pu value of the nominal voltage Vn on the **Parameters** tab is automatically adjusted to the square root of the load voltage (in pu) computed by the Load Flow tool.

## Examples

The power\_paralload example uses a Parallel RLC Load block to implement a load.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/smart-power-simulation-software-sps/blocks-functions-tools/basics/passives/parallel-rlc-load.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.