> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/smart-power-simulation-software-sps/blocks-functions-tools/basics/passives/series-rlc-load.md).

# Series RLC Load

## Description

<figure><img src="https://799605156-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FdlNg8IbOdahCpFCyzxSN%2Fuploads%2Fgit-blob-b6229f55e958d09d27ec11383738693919cf9046%2Fserie_RLC_load_block.png?alt=media" alt=""><figcaption></figcaption></figure>

The **Series RLC Load** block, located in the **OPAL-RT SPS Software/Passives** library, implements a linear load as a series combination of R L C elements. At the specified frequency, the load exhibits a constant impedance. The active and reactive powers absorbed by the load are proportional to the square of the applied voltage. Only elements associated with nonzero powers are displayed in the block icon.

## Ports

### Conserving

<table><thead><tr><th width="194.7999267578125">Port</th><th>Description</th></tr></thead><tbody><tr><td><strong>+</strong> — Positive terminal<br>SPS electrical</td><td>SPS electrical conserving port associated with the positive terminal.</td></tr><tr><td><strong>-</strong> — Negative terminal<br>SPS electrical</td><td>SPS electrical conserving port associated with the negative terminal.</td></tr></tbody></table>

## Parameters

<table><thead><tr><th width="270.800048828125">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Nominal voltage Vn (Vrms)</strong> — Nominal voltage of load<br>1000 (default) | nonnegative scalar</td><td>Nominal voltage of the load, in volts RMS.</td></tr><tr><td><strong>Nominal frequency fn (Hz)</strong> — Nominal frequency<br>60 (default) | nonnegative scalar</td><td>Nominal frequency, in hertz.</td></tr><tr><td><strong>Active power P (W)</strong> — Active power of load<br>10e3 (default) | scalar</td><td>Active power of the load, in watts.</td></tr><tr><td><strong>Inductive reactive power QL (positive var)</strong> — Inductive reactive power<br>100 (default) | nonnegative scalar</td><td>Inductive reactive power QL, in vars. Specify a positive value, or 0.</td></tr><tr><td><strong>Capacitive reactive power Qc (negative var)</strong> — Capacitive reactive power<br>100 (default) | nonnegative scalar</td><td>Capacitive reactive power Qc, in vars. Specify a positive value, or 0.</td></tr><tr><td><strong>Set the initial capacitor voltage</strong> — Option to set the initial capacitor voltage<br>off (default) | on</td><td>Select this option to specify the initial capacitor voltage. If you clear this parameter, the software calculates the initial capacitor voltage in order to start the simulation in steady state.</td></tr><tr><td><strong>Capacitor initial voltage (V)</strong> — Capacitor initial voltage<br>0 (default) | scalar</td><td>Initial capacitor voltage, in V, to use at the start of the simulation.<br><strong>Dependencies</strong>: To enable this parameter, select the <strong>Set the initial capacitor voltage</strong> parameter.</td></tr><tr><td><strong>Set the initial inductor current</strong> — Option to set the initial inductor current<br>off (default) | on</td><td>Select this option to specify the initial inductor current. If you clear this parameter, the software calculates the initial inductor current in order to start the simulation in steady state.</td></tr><tr><td><strong>Inductor initial current (A)</strong> — Initial inductor current<br>0 (default) | scalar</td><td>Initial inductor current, in A, to use at the start of the simulation.<br><strong>Dependencies</strong>: To enable this parameter, select the <strong>Set the initial inductor current</strong> parameter.</td></tr><tr><td><strong>Measurements</strong> — Measurements<br>None (default) | Branch voltage | Branch current | Branch voltage and current</td><td>Measurements to use during simulation. Place a Multimeter block in your model to display the selected measurements during the simulation. In the <strong>Available Measurements</strong> list box of the Multimeter block, the measurement is identified by a label followed by the block name:<br>Labels for Measurements:<br>Branch voltage- Ub:<br>Branch current - Ib:</td></tr></tbody></table>

### Load Flow

<table><thead><tr><th width="121.199951171875">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Load type</strong> — Option to specify the load type<br>constant Z (default) | constant PQ | constant I</td><td>Option to specify the load type.<br><br>If you select <strong>constant Z</strong>, the load impedance is determined from the nominal phase-to-phase voltage Vn, active power P, and reactive power (<a data-footnote-ref href="#user-content-fn-1">QL-QC</a>) specified on the <strong>Parameters</strong> tab of the block dialog box. During the load flow solution, the impedance is kept constant. The effective P and Q therefore vary proportionally to the square of the bus voltage computed by the Load Flow tool.<br><br>If you select <strong>constant PQ</strong>, the active power P and reactive power Q are kept constant and equal to the values specified on the <strong>Parameters</strong> tab of the block dialog box. When you apply the load flow solution to the model (by clicking <strong>Apply</strong> in the Load Flow tool), the <strong>Nominal phase-to-phase voltage Vn</strong> parameter on the <strong>Parameters</strong> tab is automatically adjusted to the phase-to-phase bus voltage computed by the Load Flow tool.<br><br>If you select <strong>constant I</strong>, the load current is kept constant at its nominal value determined from the base voltage specified in the dialog box of the associated Load Flow Bus block and from active power P and reactive power QL and QC specified on the <strong>Parameters</strong> tab of the block dialog box. The effective P and Q therefore vary proportionally to the bus voltage computed by the Load Flow tool. When you apply the load flow solution to the model (by clicking <strong>Apply</strong> in the Load Flow tool), the pu value of the nominal voltage Vn on the <strong>Parameters</strong> tab is automatically adjusted to the square root of the load voltage (in pu) computed by the Load Flow tool.</td></tr></tbody></table>

## Examples

The power\_seriesload example uses a Series RLC Load block to implement a simple load.

[^1]: **QL-QC** refers to the difference between inductive reactive power (QL) and capacitive reactive power (QC) in a three-phase load system. Inductive reactive power is associated with inductors, while capacitive reactive power is linked to capacitors. This difference is crucial for determining the overall reactive power in the system, impacting load flow calculations and system stability.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/smart-power-simulation-software-sps/blocks-functions-tools/basics/passives/series-rlc-load.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.