> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/smart-power-simulation-software-sps/blocks-functions-tools/basics/passives/three-phase-mutual-inductance-z1-z0.md).

# Three Phase Mutual Inductance Z1 -Z0

## Description

<figure><img src="https://799605156-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FdlNg8IbOdahCpFCyzxSN%2Fuploads%2Fgit-blob-1661b8d6703ef0ded7a26c1133681dff98434ac6%2F3P_mutual_indcutance_Z1Z0_block.png?alt=media" alt=""><figcaption></figcaption></figure>

The **Three Phase Mutual Inductance Z1 -Z0** block, located in the **OPAL-RT SPS Software/Passives** library, implements a three-phase balanced inductive and resistive impedance with mutual coupling between phases. This block performs the same function as the three-winding Mutual Inductance block. For three-phase balanced power systems, it provides a more convenient way of entering system parameters in terms of positive- and zero-sequence resistances and inductances than the self- and mutual resistances and inductances.

### Parameters

<table data-header-hidden><thead><tr><th width="174.79998779296875"></th><th></th></tr></thead><tbody><tr><td><strong>Positive-sequence parameters</strong></td><td>The positive-sequence resistance R1, in ohms (Ω), and the positive-sequence inductance L1, in henries (H). Default is [ 2 50e-3].</td></tr><tr><td><strong>Zero-sequence parameters</strong></td><td>The zero-sequence resistance R0, in ohms (Ω), and the zero-sequence inductance L0, in henries (H). Default is [4 100e-3].</td></tr></tbody></table>

## Examples

The **power\_3phmutseq10** example illustrates the use of the Three-Phase Mutual Inductance Z1-Z0 block to build a three-phase inductive source with different values for the positive-sequence impedance Z1 and the zero-sequence impedance Z0. The programmed impedance values are Z1 = 1+j1 Ω and Z0 = 2+j2 Ω. The Three-Phase Programmable Voltage Source block is used to generate a 1-volt, 0-degree, positive-sequence internal voltage. At t = 0.1 s, a 1- volt, 0-degree, zero-sequence voltage is added to the positive-sequence voltage. The three source terminals are short-circuited to ground and the resulting positive-, negative-, and zero-sequence currents are measured using the Discrete 3-Phase Sequence Analyzer block.

The polar impedance values are $$Z\_1 = \sqrt{2},\angle 45^\circ\ \Omega$$ and $$Z\_0 = 2\sqrt{2},\angle 45^\circ\ \Omega$$

Therefore, the positive- and zero-sequence currents displayed on the scope are

$$
I\_1 = \frac{V\_1}{Z\_1}
\= \frac{1}{\sqrt{2},\angle 45^\circ}
\= 0.7071,A ,\angle -45^\circ \\\[8pt]
I\_0 = \frac{V\_0}{Z\_0}
\= \frac{1}{2\sqrt{2},\angle 45^\circ}
\= 0.3536,A ,\angle -45^\circ
$$

The transients observed on the magnitude and the phase angle of the zero-sequence current when the zero-sequence voltage is added (at t = 0.1 s) are due to the Fourier measurement technique used by the Discrete 3-Phase Sequence Analyzer block. As the Fourier analysis uses a running average window of one cycle, it takes one cycle for the magnitude and phase to stabilize.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/smart-power-simulation-software-sps/blocks-functions-tools/basics/passives/three-phase-mutual-inductance-z1-z0.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.