> For the complete documentation index, see [llms.txt](https://www.opal-rt.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.opal-rt.com/docs/smart-power-simulation-software-sps/blocks-functions-tools/basics/passives/three-phase-parallel-rlc-load.md).

# Three-Phase Parallel RLC Load

## Description

<figure><img src="https://799605156-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FdlNg8IbOdahCpFCyzxSN%2Fuploads%2Fgit-blob-7d52803e8881af8d8e1a2ffce665d8adc5d25bb8%2F3P_parallel_RLC_load_block.png?alt=media" alt=""><figcaption></figcaption></figure>

The **Three-Phase Parallel RLC Load** block, located in the **OPAL-RT SPS Software/Passives** library, implements a three-phase balanced load as a parallel combination of RLC elements. At the specified frequency, the load exhibits a constant impedance. The active and reactive powers absorbed by the load are proportional to the square of the applied voltage.

Only elements associated with nonzero powers are displayed in the block icon.

## Parameters

<table><thead><tr><th width="178.00006103515625">Parameter</th><th>Description</th></tr></thead><tbody><tr><td>Configuration</td><td>The connection of the three phases. Select one of the following four connections:<br>Y(grounded) — Neutral is grounded. (Default)<br>Y(floating) — Neutral is not accessible.<br>Y(neutral) — Neutral is made accessible through a fourth connector.<br>Delta — Three phases connected in delta.<br>The block icon is updated according to the load connection.</td></tr><tr><td>Nominal phase-to-phase voltage Vn</td><td>The nominal phase-to-phase voltage of the load, in volts RMS (Vrms). Default: 1000.</td></tr><tr><td>Nominal frequency fn</td><td>The nominal frequency, in hertz (Hz). Default: 60.</td></tr><tr><td>Specify PQ powers for each phase</td><td>Select to specify active powers, inductive reactive powers, and capacitive reactive powers for each phase of the load. Default: cleared.</td></tr><tr><td>Active power P (W)</td><td>The three-phase active power of the load, in watts. Visible only when <strong>Specify PQ powers for each phase</strong> is cleared. Default: 10e3.</td></tr><tr><td>Inductive reactive power QL (positive var)</td><td>The three-phase inductive reactive power QL, in vars. Specify a positive value or 0. Visible only when <strong>Specify PQ powers for each phase</strong> is cleared. Default: 100.</td></tr><tr><td>Capacitive reactive power QC (negative var)</td><td>The three-phase capacitive reactive power QC, in vars. Specify a positive value or 0. Visible only when <strong>Specify PQ powers for each phase</strong> is cleared. Default: 100.</td></tr><tr><td>Active powers [Pa Pb Pc] (W)</td><td>The three-phase active power of the load, in watts. Specify three positive values (can include 0). Visible only when <strong>Specify PQ powers for each phase</strong> is selected. Default: [10e3 9e3 11e3].</td></tr><tr><td>Inductive reactive powers [QLa QLb QLc] (positive var)</td><td>The three-phase inductive reactive power QL, in vars. Specify three positive values (can include 0). Visible only when <strong>Specify PQ powers for each phase</strong> is selected. Default: [100 90 110].</td></tr><tr><td>Capacitive reactive powers [QCa QCb QCc] (negative var)</td><td>The three-phase capacitive reactive power QC, in vars. Specify three positive values (can include 0). Visible only when <strong>Specify PQ powers for each phase</strong> is selected. Default: [100 90 110].</td></tr><tr><td>Measurements</td><td>Select Branch voltages to measure the three voltages across each phase of the block terminals. For a Y connection, these voltages are the phase-to-ground or phase-to-neutral voltages. For a delta connection, these voltages are the phase-to-phase voltages.<br>Select Branch currents to measure the three total currents (sum of R, L, C currents) flowing through each phase. For a delta connection, these currents are the currents flowing in each branch of the delta.<br>Select Branch voltages and currents to measure the three voltages and the three currents of the block. Default: None.<br>Place a Multimeter block in your model to display the selected measurements during the simulation. In the <strong>Available Measurements</strong> list box of the Multimeter block, the measurements are identified by a label followed by the block name.</td></tr></tbody></table>

Measurement labels for the Multimeter block:

| Measurement     | Y(grounded) | Y(floating) | Y(neutral) | Delta |
| --------------- | ----------: | ----------: | ---------: | ----: |
| Branch voltages |        Uag: |        Uan: |       Uan: |  Uab: |
| Branch currents |        Iag: |        Ian: |       Ian: |  Iab: |

### Load Flow Tab

The parameters on this tab are used by the Load Flow tool of the Powergui block. These load flow parameters are used for model initialization only; they have no impact on the block model and on the simulation performance.

<table><thead><tr><th width="163.20001220703125">Parameter</th><th>Description</th></tr></thead><tbody><tr><td><strong>Load type</strong></td><td>Specify the load type:<br><strong>constant Z (default)</strong> — The load impedance is determined from nominal phase-to-phase voltage Vn, active power P, and reactive power (QL-QC) specified on the <strong>Parameters</strong> tab. During the load flow solution, the impedance is kept constant. The effective P and Q vary proportionally to the square of the bus voltage computed by the Load Flow tool.<br><strong>constant PQ</strong> — The active power P and reactive power Q are kept constant and equal to the values specified on the <strong>Parameters</strong> tab. When you apply the load flow solution to the model (by clicking <strong>Apply</strong> in the Load Flow tool), the <strong>Nominal phase-to-phase voltage Vn</strong> parameter on the <strong>Parameters</strong> tab is automatically adjusted to the phase-to-phase bus voltage computed by the Load Flow tool.<br><strong>constant I</strong> — The load current is kept constant at its nominal value determined from base voltage specified in the dialog box of the associated Load Flow Bus block and from active power P and reactive power QL and QC specified on the <strong>Parameters</strong> tab. The effective P and Q vary proportionally to the bus voltage computed by the Load Flow tool. When you apply the load flow solution to the model (by clicking <strong>Apply</strong> in the Load Flow tool), the p.u. value of the nominal voltage Vn on the <strong>Parameters</strong> tab is automatically adjusted to the square root of the load voltage (in pu) computed by the Load Flow tool.</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://www.opal-rt.com/docs/smart-power-simulation-software-sps/blocks-functions-tools/basics/passives/three-phase-parallel-rlc-load.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.