PROTECTION eMEGASIM OP4510 - OPAL-RT PROTECTION eMEGASIM OP4510 - OPAL-RT

PROTECTION eMEGASIM OP4510

Your Total:

Industrial Pricing

System configuration

Chassis: Intel Xeon CPU - 4 cores - 3.5 GHz, Xilinx FPGA Kintex™-7 325T

Connectivity: Ethernet port 10/100/1000 Mbps (2x RJ45) | RS232 (DB9) | USB2.0 | 5-Gbit/s high-speed fiber optic link (4x SFP)

Customize your OP4510


Hardware

I/O modules specification

You can select a maximum of 4 cards.

Analog I/O

Quantity Product Channels Resolution Voltage range Sampling frequency Price
OP5340 Analog Input 16 16 bits ± 20V 500 kS/s CAD$3,468
OP5330 Analog Output 16 16 bits ± 16V 1 MS/s CAD$3,468

Digital I/O

Quantity Product Channels Voltage range Rising Time Price
OP5360 Digital Output 32 5V to 30V 65 ns CAD$2,187
OP5353 Digital Input 32 4.5V to 50V 40 ns CAD$1,800
Choosing your Hardware Configuration
Measurement solution | Optional driver for I/O

RS422 Adapter
OP4510 V2-1 RS422 Connectors
DB9 connector module for RS422 signals, typically used to transmit differential encoder inputs and outputs. Transmit and receive 6 digital, 6 PWM, or 2 encoder signals.

CAD$912

Selectable 32 timed-stamped digital inputs and 32 timed digital outputs for OP4510
Timed Generation and Measurement Firmware
Capture and generate three-phase PWM, and other timed signals, with high-precision. Perform fast measurement and analysis of timed signals. The firmware provides its own MATLAB®/Simulink® blockset.

CAD$1,434

Software

Protection Application | Default software

eMEGASIM FX75
Specialized power system solver add-on to RT-LAB to optimize Simscape power system real-time performance. eMEGASIM is largely used in microgrid and DER(Distributed energy Resources) applications.

Improve the performance of your system | Optional Software

Waveform Visualization and Analysis SoftwareRECOMMENDED
ScopeView for HYPERSIM® HX30
ScopeView is used for signal visualization, data analysis and monitoring. In both real-time and offline modes, ScopeView displays, analyzes and compares waveforms acquired from various environments, data acquisition systems and field equipment.

CAD$1,676
Choosing your Software Solution

Communication protocols

Time Synchronization GPS, IEEE 1588, 1PPS, IRIG-B with RJ45 connectors
Time synchronization card RJ45
The OP3811-RJ45 board is required for accurate time synchronization (0.1 ppm oscillator) and provides RJ45 connections.

CAD$6,145

Time Synchronization GPS, IEEE 1588, 1PPS, IRIG-B with SFP connectors
Time synchronization card SFP
The OP3812-SFP board is required for accurate time synchronization (0.1 ppm oscillator) and provides SFP connections.

CAD$6,145

Serial communication protocol using TCP-IP, RTU or ASCII interfaces
Modbus Master
Modbus is an easily deployable, simple and robust serial communication protocol. The Modbus master is a virtual device that actively polls data from one or multiple devices (slave). Capable of polling up to 50 data points.

CAD$3,491

Serial communication protocol using TCP-IP, RTU or ASCII interfaces
Modbus Slave
Modbus is an easily deployable, simple and robust serial communication protocol. The Modbus slave is a virtual passive device, waiting for the master to poll data. Capable of receiving and transmitting up to 50 data points.

CAD$3,491

Distributed Network Protocol slave
DNP3 Slave
DNP3 is used between components in process automation systems. The slave is the counterpart of the master. It is a virtual passive device, waiting for the master to poll data. Capable of receiving and transmitting up to 50 data points.

CAD$3,491

Distributed Network Protocol master
DNP3 Master
DNP3 is used between components in process automation systems. The master is a virtual device that actively polls data from one or multiple devices (slave). Capable of polling up to 50 data points.

CAD$3,491

Slave communication protocol for PMU interface and synchrophasor
C37.118 Slave
C37.118 protocol defines synchrophasors, frequency, and rate of change of frequency (ROCOF) measurement under all operating conditions. The slave is the counterpart of the master. It is a virtual passive device, waiting for the master to poll data. Capable of receiving and transmitting up to 50 data points.

CAD$3,491

Master communication protocol for PMU interface and synchrophasor
C37.118 Master
C37.118 protocol defines synchrophasors, frequency, and rate of change of frequency (ROCOF) measurement under all operating conditions. The master is a virtual device that actively polls data from one or multiple devices (slave). Capable of polling up to 50 data points.

CAD$3,491

IEC 61850-9-2 Sampled Values data integrity manipulation
IEC 61850-9-2 SV DIM
IEC 61850-9-2 Sampled Values data integrity manipulation, lets the user manipulates quality bits or inject one or multiple faults in the IEC 61850-9-2 streams.

CAD$1,466

Sampled Value communication protocols for protection relay interface
IEC 61850-9-2 SV
The IEC 61850-9-2 Sampled Values provides fast transmission and reception of voltages, currents and status information between transformers and transducers (CT, PT?), and primary power system equipment. Simulators can be used to emulate merging unit or to receive data from real merging unit. Publisher and Subscriber with up to 50 data points.

CAD$3,491

GOOSE Communication protocols for protection relays
IEC 61850-8-1 GOOSE
The IEC 61850-8-1 GOOSE provides high speed (< 4 ms) peer-to-peer exchange of status and control commands between logical nodes of the substation protection, control, monitoring and logging systems. Publisher and Subscriber with up to 50 data points.

CAD$3,491
Choosing your Communications Protocol(s)
Shop