Knowledge Base
Welcome to OPAL-RT’s Knowledge Base
OPAL-RT offers a repository of support information for optimal use of its technology.
Please note that OPAL-RT knowledge base is not fully optimized for mobile platforms.
For optimal experience, use a desktop computer.
Reference Number: AA-01514// Views: AA-01514// Created: 2018-07-18 20:45:50// Last Updated: 2018-07-18 20:47:52 Problem & Solution LabVIEW Error 7 When Generating Matrices in eHS Real Time Power Electronics Simulation Toolbox ProblemI am using the eHS Real Time Power Electronics Simulation Toolbox for LabVIEW to compile and load a circuit model onto an NI system. When generating eHS matrices using gen_eHS_mtx.vi, I receive the following error: Error 7 occurred at Open File+.vi:Open File How can I resolve the error? SolutionThe circuit model must be placed in the same directory as the example LabVIEW project, in the folder called PSIM_Multisim_SPS_Models. This is the same location as the example circuit models. Note that this information is specific to the following LabVIEW toolkits: Open eHS Real-Time Power Electronics Simul Toolbox (NI PXIe-7976R) |