Reference Number: AA-01961// Views: AA-01961// Created: 2020-10-19 18:33:11// Last Updated: 2020-11-09 14:49:54 Problem & Solution HYPERSIM: End of acquisition POW not detected ProblemI get this error on using ScopeView with HYPERSIM: SolutionOne of the reasons that this error pops up is due to the incorrect configuration of the POW block. The first thing is to check all settings in the POW block, especially the detection level. For example, consider the case when the detection level in POW block is set to 26kV and we get this error in ScopeView.
Thus, the detection level is never crossed and so we get the error "End of acquisition POW not detected" in ScopeView.
Note: The error "End of acquisition POW not detected" can also occur if the HYPERSIM model diverges (i.e. values are NaN) and thus we never cross the detection level specified in the POW block. |