Power Systems

Overcurrent relay coordination testing for modern distribution feeders

Power Systems

07 / 28 / 2026

Overcurrent relay coordination testing for modern distribution feeders

This piece explains how overcurrent protection coordination is set, checked, and tested on distribution feeders where local generation alters fault current magnitude and direction.

Why distance protection relays mis-reach under real fault conditions

Power Systems

07 / 25 / 2026

Why distance protection relays mis-reach under real fault conditions

This piece explains why distance protection relays mis-reach under fault resistance, source infeed, capacitive voltage transformer transients, and heavy transfer, and how simulation-based testing checks zone reach before energization.

Automating grid code compliance testing for inverter-based plants

Power Systems

07 / 23 / 2026

Automating grid code compliance testing for inverter-based plants

Grid code compliance testing for inverter plants depends on weak grid studies, fixed disturbance definitions, repeatable scripted sequences, and structured pass/fail evidence.

Low voltage ride through testing for grid connected inverters

Power Systems

07 / 21 / 2026

Low voltage ride through testing for grid connected inverters

A practical guide to LVRT test methods, voltage sag profile fidelity, protection checks, and pre-connection verification for grid-connected inverters.

Shipboard and marine power systems tested in a closed loop

Power Systems

07 / 18 / 2026

Shipboard and marine power systems tested in a closed loop

This guide explains how closed-loop, real-time simulation is used to validate marine power system controls, protection timing, and fault response before sea trials.

Testing wide area protection and control schemes in real time

Power Systems

07 / 14 / 2026

Testing wide area protection and control schemes in real time

This page explains how engineers test wide area protection, wide area monitoring, and synchrophasor control schemes with timing budgets, latency checks, and closed-loop validation.

Process bus and sampled values testing for digital substations

Power Systems

07 / 10 / 2026

Process bus and sampled values testing for digital substations

Process bus testing, sampled values validation, and merging unit checks are examined through timing, mapping, and relay response tested as one synchronized system.

What substation automation testing misses without a real-time model

Power Systems

07 / 09 / 2026

What substation automation testing misses without a real-time model

Guidance on testing a substation automation system focuses on scenario based, time-aligned, closed-loop validation before commissioning.

How current transformer saturation distorts differential protection testing

Power Systems

07 / 08 / 2026

How current transformer saturation distorts differential protection testing

A practical review of current transformer saturation, its effect on bus differential protection, and how to test relays with feeder-specific saturated waveforms.

Validating out of step protection with real-time fault simulation

Power Systems

07 / 06 / 2026

Validating out of step protection with real-time fault simulation

Engineers use closed-loop simulation to validate out-of-step protection and power swing protection, from relay logic and settings to stable and unstable swing tests.