Back to blog

Six-phase and 12-phase motors, and why multi-phase PMSMs are winning in eVTOL and EV traction

Automotive

11 / 15 / 2026

Six-phase and 12-phase motors, and why multi-phase PMSMs are winning in eVTOL and EV traction

Key Takeaways

  • Multi-phase PMSMs keep producing torque after a winding or inverter fault, which suits eVTOL aircraft that can’t lose a rotor.
  • Splitting power across more phases lowers current per phase, easing inverter design in heavy-duty traction drives.
  • Magnetic coupling between winding sets makes multi-phase control hard, so the full machine has to be modelled for HIL to be trustworthy.

Multi-phase PMSMs are winning in eVTOL and EV traction because they keep producing torque after a fault and spread current across more phases, and those benefits only hold if the control is validated against the full multi-phase machine.

Aviation regulators have made fault tolerance a design priority. The FAA’s powered-lift rule, published in October 2024, created the first new category of civil aircraft since helicopters arrived in the 1940s, and electric vertical takeoff aircraft in that category have to keep flying through the loss of a motor phase or an inverter leg.

That requirement is reshaping motor design well beyond aviation. Six-phase and 12-phase machines that once lived in ship propulsion and large industrial drives are now appearing in traction motors, where the same redundancy and current sharing solve different problems.

What a 6-phase motor adds over a 3-phase machine

A 6-phase motor has two sets of three-phase windings, usually shifted by 30 electrical degrees and fed by two inverters. It produces smoother torque, carries half the current per phase at the same power and can keep running on one winding set if the other fails.

The 30 degree shift is what makes the configuration attractive. It cancels some of the torque ripple harmonics a 3-phase machine produces, and it lets the two inverters share the load evenly in normal operation. If one inverter trips, the other can carry the motor at reduced power instead of leaving the vehicle with nothing.

Why fault tolerance makes multi-phase motors fit eVTOL

Fault tolerance makes multi-phase motors fit eVTOL because a single electrical fault can’t be allowed to stop a rotor that holds the aircraft in the air. Extra phases and independent inverters give the drive enough redundancy to keep producing controlled thrust after a winding, switch or sensor failure.

Certification turns that redundancy into a measurable requirement. Designers have to show that the motor survives a fault, how quickly the controller reconfigures and how much torque remains during the transition. Regulators won’t accept a redundancy argument that hasn’t been demonstrated across the flight envelope. A few milliseconds of torque loss at the wrong moment in a hover can matter.

Multi-phase designs also help with weight. Splitting power across more phases lets each inverter use smaller devices and cables, which can offset the extra hardware the redundancy requires. For an aircraft where every kilogram trades against range and payload, that offset is often what makes a redundant drive viable at all.

The result is a drive that degrades gracefully instead of failing outright, which is the behaviour aviation certification expects from every safety-critical system.

How multi-phase PMSMs lower current per phase in traction drives

Bar comparison showing that a 6-phase machine carries half the phase current of a 3-phase machine at the same voltage and power.

Multi-phase PMSMs lower current per phase by dividing the machine’s power across more windings. At the same voltage and power, a 6-phase machine carries half the phase current of a 3-phase one, which lets designers use smaller switches, thinner cables and inverters that run cooler.

Heavy-duty traction is where that matters most. Electric truck sales reached 9% of all truck sales worldwide in 2025, and the power levels in those drivetrains push 3-phase inverters toward device ratings that are expensive or hard to source. Splitting the load across two or four three-phase sets brings each inverter back into a comfortable range. Fleet operators also value the limp-home behaviour, since a truck that can reach a depot on half its winding sets avoids a roadside tow.

“A model that treats them as independent 3-phase machines will pass control designs that misbehave on real hardware.”

What a 12-phase PMSM gains from added phase redundancy

Animation of a 12-phase PMSM with four winding sets losing one set to a fault while 75% of winding capacity remains in service.

A 12-phase PMSM uses four three-phase winding sets, so it can lose one set and keep 75% of its winding capacity. It also reduces torque ripple further and spreads current across four inverters, which suits high power drives where both availability and smooth torque are critical.

The table compares the three common configurations.

Configuration Main advantage Main trade-off
3-phase PMSM Simple, mature and supported by every standard inverter A single phase or switch failure usually stops the drive
6-phase PMSM Half the current per phase and continued operation on one winding set Two inverters and more complex current control
12-phase PMSM Operation after losing one of four sets and very low torque ripple Four inverters and strong coupling between winding sets
3-phase open-end winding Access to both winding ends for flexible control and fault analysis Two inverters per machine and zero-sequence current to manage
Modular multi-motor layout Redundancy through several separate motors on one shaft or rotor More weight and mechanical complexity than one multi-phase machine

“A few milliseconds of torque loss at the wrong moment in a hover can matter.”

Why multi-phase machines are harder to control than they look

Multi-phase machines are harder to control because their winding sets are magnetically coupled. Current in one set induces voltage in the others, so each inverter’s control loop affects its neighbours, and faults change that coupling in ways a simple 3-phase model can’t represent.

Control teams usually work through a familiar set of problems.

  • Circulating currents between winding sets that add losses without adding torque
  • Current sharing errors when inverters see slightly different DC link voltages
  • Torque transients during reconfiguration after a winding set is disabled
  • Harmonic currents in the additional sequence planes of the machine
  • Protection logic that has to isolate one set without tripping the others

Each of these depends on how strongly the winding sets interact. A model that treats them as independent 3-phase machines will pass control designs that misbehave on real hardware. The coupling also shifts with saturation and temperature, so a controller tuned at room temperature and light load can’t be assumed stable at peak torque on a hot day.

How to simulate a multi-phase motor in real time

Simulating a multi-phase motor in real time requires a model that represents all winding sets and the magnetic coupling between them at microsecond or faster timesteps. The real controllers then connect to the simulated machine and inverters, so fault and reconfiguration behaviour can be tested without risking a prototype motor.

OPAL-RT added electromagnetically coupled 6-phase and 12-phase PMSM models and a 3-phase open-end winding model to RT-LAB in its 2025.4 release, in response to traction and aerospace teams who needed to test these machines as built. With coupling represented, engineers can disable a winding set mid-run and watch exactly how the remaining controllers respond.

That capability turns fault tolerance from a design claim into tested behaviour. The same fault can be applied at every speed and torque point, and the results become evidence for certification. It’s also where control teams catch their subtlest bugs, such as a current sharing loop that’s stable with four healthy sets and oscillates with three.

What validated multi-phase drives mean for certification programs

Validated multi-phase drives give certification programs evidence that fault tolerance works in practice, with recorded reconfiguration times and torque profiles for every relevant fault. That evidence shortens the path from a promising motor design to a drive that regulators and customers will trust.

We see eVTOL and traction teams reach that point faster when they model the full machine from the start instead of approximating it. OPAL-RT‘s Power in Mind Volume 12 covers the customer need behind these multi-phase models in depth, and the full issue is the best next read for teams weighing a 6-phase or 12-phase design.