Problem & Solution
Error 4: Unable to flash bitstream, bitstream extension must be '.bin'

Problem

When I try to load my model, I always get the following error even though all RT-LAB settings are fine.

ERROR: Bitstream extension must be '.bin'



Solution

This error appears when the model absolute path is too long (more than 255 characters).

When this happens, RT-LAB is unable to retrieve the bitstream file and therefore fails to flash the FPGA.

The solution is to reduce the path of the model. The easiest way is to shorten the model name and then import it again under a shorter project name.