Problem & Solution
ARTEMiS: Smart Inverter Library Error to Build the Model

Problem

You got an error that “SMARTINVERTER feature not founded” when try to build RT-LAB model with Smart Inverter Library blocks.



Solution

To solve this issue, first, check if you are using ARTEMiS 7.7.2 version or newer. For this use the “ver” command on Matlab.

Additionally, to be able to use these blocks you must have the SMARTINVERTER library available on the HOST and TARGET licenses for RT-LAB (it is mandatory to have it on both licenses).

To request and install a license you can follow the KBs:

How To Request and Install a License for RT-LAB 11.x+

RT-LAB 11.x+ "localhost" License Activation