Problem & Solution
[RT-LAB + eHS Gen 3] Two Level Bridge Example Model Not Running Offline

Warning
 Please note this is a legacy Knowledge Base article, eHS Gen 3 is not maintained since 2018.

Problem


The error below appears when trying to run the example demo model "two_level_bridge_rtlab" from eHS Gen 3:


Undefined function 'efsSolverInfo' for input arguments of type 'char'.




How to solve it?



Solution


Step 1. Close the Simulink model

Step 2. In the MATLAB Command Window, run the m-script coming from C:\OPAL-RT\EFPGASIM\v1.4.X.XXX\eFPGAsim_m by navigating to the location and dragging and dropping the file to the Command prompt.