Problem & Solution
"Argument to denamic structure reference must evaluate to a valid field name error" in ePHASORsim

Problem

When I run Excel-input ePHASORsim model with FMU, I got error message as below. How can I solve it?

 

Solution

A possible reason is that the FMU parameters page in Excel contains "NaN" data value. You can check detail reason on the in section of ePHASORsim User Guide. Please note this FMU parameters page is user defined, so currently ePHASORsim cannot valiate this page and return error message as shown in User Guide. 

To solve it, please locate and correct the corrupted data cell. If no data cells are obviously blank, a cell in an empty row or column could be causing the issue. Delete the rows surrounding all data by selecting the entire rows and columns and using ‘Delete’ in the right-click menu. Alternately, user can try to re-create this FMU parameters page and make sure [Del] key is not used.