Problem & Solution
Frames/sec not as expected in PMU Connection Tester

Problem

I run a simulation containing C37.118 slave and in "Open PDC / PMU Connection Tester" the configured frame rate is different than the actual Frames/sec.



Solution

1- Ensure that the configured frame rate can be achieved according to the timestep of the simulation. For instance, if 120 frames/sec is needed, ensure that the timestep is less than 1/120 = 8.333ms.

2- Ensure that the simulation is running in real-time. Thus, the simulation is not generating constant overruns.