HYPERSIM
Error With Page Connector in HYPERSIM: Can’t Open HYPERSIM Component Form Error With Page Connector in HYPERSIM: Can’t Open HYPERSIM Component FormWhen
double-click on Page Connector, the following error occurs: Can’t open HYPERSIM
Component Form. The
Page Connector has the ability to connect signals by Name. In this way, the
parameter that is available to be configured in this element is the name, that
can be accessed by right click on Page Connector > Name. To connect both signals using Page give them the same name. More information about Page Connectors can be founded on Page Connector Wiki Page. The
signal name defined can be visible or not. If a Page Connector has no Name visible,
open the name configurations to find it.
Important:
the name definition is case sensitive, so exactly the same name must be provided
for both signals that are being connected. |