Knowledge Base
Welcome to OPAL-RT’s Knowledge Base
OPAL-RT offers a repository of support information for optimal use of its technology.
Please note that OPAL-RT knowledge base is not fully optimized for mobile platforms.
For optimal experience, use a desktop computer.
Reference Number: AA-02130// Views: AA-02130// Created: 2023-02-17 18:00:55// Last Updated: 2023-02-17 20:38:38 Problem & Solution Error 2 or Error 5 Occur When Working With Reflective Memory in RT-LAB ProblemMy simulator is equipped with a VMIC 5565 reflective memory card. When I add the Reflective memory blocks (OpRFM) to my Simulink model to read or write in the reflective memory, I get the following error when loading the model on my simulator: Error while Loading model Error 2 : Unable to register Node OR Error while Loading model [model name] Error 5 : Error receiving Loading information from one subsystem. RT-LAB wasn't able to successfully load the model: Please see the load log(s) for more details Also, when trying to load the model again, RT-LAB might report this error: Error code 6 from OpalInit. Unable to assign target resources needed by simulation SolutionIn addition to being placed in the same folder as the Simulink, the reflective memory configuration file(s) must also be added to the model's "Files" tab in RT-LAB: Simulink model: RT-LAB: Make sure to set the Transfer time to "Before Load" and Mode to "ascii" |