Reference Number: AA-02178
// Views: 22
// Created: 2023-05-11 12:27:41
// Last Updated: 2023-05-11 12:31:12
Problem & Solution
Error 14: Cannot Load the Simulation Model on This Platform, Please Close LabView Panels First ProblemWhen you try
to run an RT-LAB model with Labview Panels, and when loading the following
error occurs: SolutionThis problem
happens because the targets with OPAL-RT Linux OS had the RTLAB_FORCE_LABVIEW_PANELS_ACTIVATION environment variable
equals to zero, what let the LabView Panels deactivated.
To solve this issue, you should double click on the model name, go to
the Variables tab, click on Add: Choose the RTLAB_FORCE_LABVIEW_PANELS_ACTIVATION (check if its values is
equal to 1) It will appear on the Environment Variable Properties: |