Support : Knowledge base

Knowledge Base

Welcome to OPAL-RT’s Knowledge Base

OPAL-RT offers a repository of support information for optimal use of its technology.

Loading…

Please note that OPAL-RT knowledge base is not fully optimized for mobile platforms.

For optimal experience, use a desktop computer.

Reference Number: AA-02178// Views: AA-02178// Created: 2023-05-11 12:27:41// Last Updated: 2023-05-11 12:31:12
Problem & Solution
Error 14: Cannot Load the Simulation Model on This Platform, Please Close LabView Panels First

Problem

When you try to run an RT-LAB model with Labview Panels, and when loading the following error occurs:


Solution

This problem happens because the targets with OPAL-RT Linux OS had the RTLAB_FORCE_LABVIEW_PANELS_ACTIVATION environment variable equals to zero, what let the LabView Panels deactivated.

To solve this issue, you should double click on the model name, go to the Variables tab, click on Add:


Choose the RTLAB_FORCE_LABVIEW_PANELS_ACTIVATION (check if its values is equal to 1)


It will appear on the Environment Variable Properties: